Mr ManhThis year we are going to build a mobile phone screen electronics clean factory.We send Hongkong YaNing a list of products we need,Unexpectedly, they soon gave me a very detailed quotation and drawings, and gave us a lot of good advice. Very professional, good service, good product quality! We decided to place an order.
Negative Pressure Laminar Flow Hood 400m3/h For Infectious Ward
Product Name | Negative Pressure Laminar Flow Hood | Purification Levels | Class 100 |
---|---|---|---|
Specification | 550*550*400mm | Hepa Size | 450*450*70mm |
Adhibition | Infectious Ward Of Hospital | Air Volume | 100-400m3/h |
Material | Powder Coating Steel ,stainless Steel Steel | Warranty | 12 Months |
High Light | Negative Pressure Laminar Flow Hood,Infectious Ward Laminar Flow Hood,400m3/h Laminar Air Flow Hood |
Negative pressure laminar flow hood isolation air for infectious ward of hospital
1. Negative pressure laminar flow hood description
Negative pressure laminar flow hood isolation air contaminat i on control system ideal for hospitals, extended care facilit i es, ande megency preparedness centers. This system maintains a sterile envi-ronment in an isolated room, which prevents cross-contaminat i ont houghout the rest of the facility— creat i nga bt er environment for pat i ets and staff.
In addit iono providing strict temperature and humidity control,Isolat i onAiris equipped with on-board HEPA filtrat i on, UVterilizat i on, andd uct ork connect i o ns. Thi s ystem is capable of quickly convert i ngatandard-sized pat i et room into a negat i e or posit i e pressure environment.
2. Negative pressure laminar flow hood isolation air ombines known technologies into an easy-to-deploy portable unit
• HEPA filtrat i onor airborne part i cul te removal
• UV light to aide in sterilizing airborne viruses and bacteria trapped on the HEPA
• Pressure control either negat i e or posit i e
- Infect i o usdi s easeontrol (TB, SARS, smallpox, etc.) requires negat i e
- Protect i e environment control (burn, immuno-suppressed) is posit i e
• Temperature control – the room becomes isolated from the central system
- Only air having passed through both UV and HEPA will be returned to hospital HVAC
3. Laminar air flow ceiling Parameter
Model/parameter | Class Ⅰ | Class Ⅱ | Class Ⅲ |
Efficiency | 99.99% | ||
The wind speed(m/s) | 0.45 | 0.3 | 0.23 |
Air supply size (mm) | 2600×2400 | 2600×1800 | 2600×1400 |
Boundary dimension (mm) | 2680×2480×500 | 2680×1880×500 | 2680×1480×500 |
Hepa size and QTY | 610*305*292mm 8pcs | 610*305*292mm 6pcs | 610*305*292mm 4pcs |
Usage occasion | Class Ⅰ Special clean operating room. | Class ⅡStandard clean operating room. | Class Ⅲ General clean operating room. |
Our products
1.FFU ,air shower room ,cargo air shower ,HEPA filter ,horizontal clean bench ,pass box ,clean booth medical bench and so on
2.primer,middle and HEPA filter ,sub-high efficiency filter
3. undertake 1-300 thousand class level clean room design and construction of the project commission inspection and maintenance.