Hongkong Yaning Purification industrial Co.,Limited violaquan@dgync.com 86--18373128025
Product Details
Place of Origin: China
Brand Name: YN
Certification: CE/ISO
Model Number: YN-MHF
Payment & Shipping Terms
Minimum Order Quantity: 10 pcs
Price: Reconsideration
Packaging Details: First in pp bag,then in carton,final made a wooden box. or as your requirement.
Delivery Time: 7-30 workdays
Payment Terms: L/C, T/T, Western Union
Supply Ability: 1000pcs/month
Product Name:: |
Mini Pleated Hepa Filter |
Frame:: |
304 Stainless Steel Frame |
Size:: |
610*610*90mm Or Custom |
Gasket:: |
EVA/ Polyurethane |
Filter Media:: |
Glass Fiber |
Air Volume:: |
2000m3/h |
Package:: |
First In PP Bag,then In Carton,final Made Wooden Case |
Terms: |
FOB/CIF/EXW |
Product Name:: |
Mini Pleated Hepa Filter |
Frame:: |
304 Stainless Steel Frame |
Size:: |
610*610*90mm Or Custom |
Gasket:: |
EVA/ Polyurethane |
Filter Media:: |
Glass Fiber |
Air Volume:: |
2000m3/h |
Package:: |
First In PP Bag,then In Carton,final Made Wooden Case |
Terms: |
FOB/CIF/EXW |
1. Description
The hepa filter without separators removes the corrugated partition plate in the traditional structure and uses ultra-fine glass fiber as the filter material, the hot melt adhesive as the separator of the filter element, and various types of outer frame equipment. Suitable for non-unidirectional flow clean room projects that require severe unidirectional flow and high levels. At present, Class A clean rooms generally use non-separator high-efficiency filters, and FFU is equipped with high-efficiency filters without partitions. Compared with hepa filters with separators, it has small volume, light weight and compact structure under the same air volume. The utility model is reliable, and is convenient for equipment, power stability, uniform wind speed and the like. Efficient plan without partitions can reach the highest power with minimum resistance, and then reduce the cost of work. In particular, the planned hot melt adhesive can guarantee the same fold interval, ensure the passage of airflow, and reach high dust capacity together, prolonging service life. Fully utilize the filter media at full depth. Under the conditions of the equivalent standard! The amount of ventilation is not the same as the amount of dirt!
Advantages
Filter efficiency ranges from U15 to U17.
Adopt computer-controlled automatic production line for manufacturing, the crest height of folding filter material can be regulated steplessly between 18~96 mm, width will reach 1240mm at the widest.
Use special ultra-fine fiberglass filter paper as the filter material, good stability of filtration efficiency.
Double side retainers, protect the filter media, good strength.
Light in weight, compact in structure.
Each ULPA filter is tested according to EN1822:2009.
Material Instructions
Media: Ultra-fine fiberglass or PTFE filter paper.
Frame: Anodised aluminium or stainless steel.
Separator: Hot-melt glue.
Sealant: Polyurethane.
Temperature: Maximum 90°C in continuous service.
Application
Suitable for electronics, pharmaceutical industry, clean room, FFU, laminar flow devices, and the occasions require ultra-high cleanliness.
Model |
Nominal Size WxHxD (mm) |
Air volume m³/h |
Dust capacityg |
Surface Wind Speed (m/s) |
Initial Resistance (pa) |
Efficiency (Colorimetric Method/Class) |
YN-MHF | 320*320*96 | 500 | about 450 | 0.35 |
≤220 |
H13/H14 |
YN-MHF | 610*610*69 | 700 | 700 | 0.35 | ||
YN-MHF | 484*484*96 | 1000 | 650 | 0.45 | ||
YN-MHF | 610*610*90 | 1200 | 950 | 0.45 | ||
YN-MHF | 630*630*96 | 1500 | 800 | 0.6 | ||
YN-MHF | 915*610*96 | 2000 | 1200 | 0.6 | ||
YN-MHF | 1220*610*96 | 3000 | 1600 | 0.6 | ||
Special size can be customized |
4. Mini pleats hepa filter installation
1, can be used with a variety of brand FFU installed on ceiling keel or color plate ceiling.
2. The HEPA filter needs to be installed in the air duct, and is to be blown into the room, and installed after the air volume and indoor cleanliness meet certain requirements, in order to prolong the service life of the HEPA filter.
3, in order to guarantee the service life of the high-efficient filter, it is recommended that before the air enters, it must pass a pre-filter which is not lower than F8 (colorimetry 90%-95%).